This example demonstrates a simplified post-combustion carbon capture process using an aqueous solvent to absorb CO₂ from flue gas and subsequently release it through desorption. The model includes gas–liquid mass transfer, solvent recirculation and heat input to investigate the effect of operating conditions on CO₂ capture performance.
Industry: Oil & Petrochemical, Fossil Fuel Power Generation |
PROJECT FILE
The network can be downloaded by clicking on the download button below:
NETWORK DESCRIPTION
The network, shown in Figure 1, represents a simplified carbon capture process.
Flue gas enters the absorber, where CO₂ is absorbed by an aqueous solvent. The CO₂-rich solvent exits at the bottom, while the flue gas, with a reduced CO₂ content, leaves at the top. The rich solvent then passes through a heat exchanger before entering the desorber, where heating promotes the release of CO₂ and steam. These gases leave through the top of the desorber, while the CO₂-lean solvent exits at the bottom, passes back through the heat exchanger and returns to the absorber.
The working fluid is modelled as a two-phase liquid–gas mixture. The flue gas composition is defined using the mass fractions of the gases produced by the combustion of methane in air. The aqueous solvent is modelled as water, with varying CO₂ mass fractions used to represent the absorption and release of CO₂ throughout the process.
Absorber
The absorber is implemented as a compound component consisting of Flow Resistance components, Boundary Condition components and a Script. The Script calculates the amount of CO₂ absorbed based on the user-specified maximum CO₂ concentration in the solvent leaving the absorber. The corresponding CO₂ mass flow rate is transferred from the flue gas stream to the solvent stream using mass flow rate boundary conditions.
Desorber
The desorber is also implemented as a compound component that consists of Flow Resistance components, Boundary Condition components, an Open Container component, a Steam/Water Trap component and a Script. The Script determines the amount of CO₂ released based on the user-specified CO₂ concentration in the lean solvent leaving the desorber. The corresponding CO₂ mass flow rate is removed from the solvent and discharged through the exhaust.
A reboiler provides the heat input required to achieve the specified solvent outlet temperature and promote CO₂ release.
Network Inputs and Outputs
The Track Bars, shown in Figure 1, allow the following input parameters to be adjusted using the corresponding scroll bars:
Mass flow rate of flue gas entering the absorber.
Maximum CO₂ absorption capacity of the solvent.
Aqueous solvent mass flow rate.
Reboiler outlet temperature. This should be kept below 90°C to prevent the reboiler from boiling dry.
The main outputs to monitor are:
CO₂ mass fractions at various points throughout the network.
CO₂ mass flow rates absorbed in the absorber and released in the desorber.
Heat input required by the reboiler.
RUNNING THE SIMULATION
The network is intended to be solved under steady-state conditions. The CO₂ absorption and desorption calculations are performed on a quasi-steady-state basis, and thermal inertia is not included.
- Load the "CO2 Steady state" snap.
- Solve the network in steady state.
- Run a transient simulation.
- Use the Interact tool to adjust the Track Bars and observe the resulting changes in system performance.